Orifice & Valve Flow Rate Calculator
Enter a bore and a pressure drop — or a Cv and a duty point — and read the flow rate back in GPM and L/min on the same keystroke. Liquid mode sizes orifices, nozzles, venturis, and control valves from density and ΔP; gas mode adds the choked-flow boundary, the point past which extra pressure drop stops buying extra flow.
This page is the dedicated orifice flow rate calculator of the Flow Calculator toolset: the restriction math the main flow rate engine summarizes in one line, pulled out and given its own inputs, verdicts, and presets — and the calculators hub lists every other tool that shares its engine.
The Calculator — Liquid and Gas Modes
Every field recalculates the results panel instantly — there is no submit button. The three preset buttons load the worked examples used elsewhere on this page, so you can verify the math against them in one click.
Liquid mode — pressure drop to flow, and back
Volumetric flow through the restriction
41.4 L/min
10.93 GPM
- Mass flow
- 2,477 kg/h · 5,460 lb/h
- Jet velocity at the vena contracta
- 14.16 m/s · 46.44 ft/s
- v = √(2·ΔP/ρ) — the ideal jet speed the pressure drop can drive.
- Bore area A = πd²/4
- 78.54 mm²
- Discharge coefficient
- Cd 0.62
- Permanent pressure loss (orifice approx.)
- 73 % of ΔP ≈ 73.2 kPa
- Engineering approximation ΔP_loss ≈ ΔP·(1 − β^1.9) at β = 0.5; the drop measured at the taps that never comes back.
Before you trust the number
This calculator provides preliminary estimates for planning and education. It is not a substitute for design by a licensed engineer, manufacturer datasheets, or applicable codes (ISO 5167, IEC 60534).
How the Orifice and Valve Equations Work
Two families of equations cover nearly every restriction you will meet. Physical restrictions — a drilled orifice plate, a flow nozzle, a venturi — convert pressure into velocity, and their flow follows the orifice equation:
- Q — volumetric flow, what you are solving for.
- A = πd²/4 — the bore area, from the actual opening diameter.
- Cd — the discharge coefficient: how far the real device falls short of the ideal frictionless jet.
- ρ — the fluid density at operating conditions.
- ΔP — the pressure drop measured across the taps.
The discharge coefficient is the honesty term in the equation. A sharp-edged plate forces the jet through a vena contracta narrower than the bore and spends energy in turbulence, so only about 62 % of the ideal jet survives as real flow; a streamlined nozzle or venturi guides the flow instead of letting it contract, and keeps 95–99 % of it. The formulas section of the homepage places these equations next to the pipe-flow family they plug into — the loss a restriction creates is the first entry in a line’s friction budget.
Control valves use a different, calibration-based equation. Instead of geometry, the manufacturer publishes a flow coefficient measured on water:
Here SG is the specific gravity of the liquid relative to water at 20 °C (SG = ρ / 998.2), and the two coefficients describe the same valve on two calibrations: Kv = 0.865·Cv and Cv = 1.156·Kv. Everything else — the square-root response to pressure drop, the linear response to the coefficient — is identical.
Don’t mix the two coefficients in one equation. Cv expects GPM and psi; Kv expects m³/h and bar. Substituting a Kv number into the Cv equation — or the reverse — shifts every result by about 16 %, exactly the gap between 1 psi and 1 bar, and nothing in the output warns you it happened.
Liquid Flow Through an Orifice: Worked Example
Load the first preset — 10 mm orifice · water · 100 kPa — and the panel reproduces the classic hand calculation live. Step through it once and every number in the results row has a name:
- Bore area. A = π·(10 mm)²/4 = 78.54 mm² — the opening itself, not the pipe cross-section.
- Jet velocity. v = √(2·ΔP/ρ) = √(2 × 100,000 / 998) = 14.16 m/s — the speed the pressure drop can drive.
- Real flow. Q = 0.62 × 78.54 mm² × 14.16 m/s = 6.89×10⁻⁴ m³/s — that is 41.4 L/min ≈ 10.9 GPM.
- Mass flow. ṁ = ρ·Q = 998 × 6.89×10⁻⁴ = 2,477 kg/h (5,460 lb/h) — the number a process balance wants.
- Permanent loss. At β = 0.5, ΔP_loss ≈ 100 × (1 − 0.5^1.9) ≈ 73.2 kPa — most of the drop is destroyed, not recovered.
The square-root law is visible right inside the example: raise the drop from 100 to 400 kPa and the flow only doubles, from 41.4 to 82.8 L/min. That diminishing return is the single most useful habit the equation teaches — and the reason “just add pressure” is an expensive way to buy flow.
Treat Cd as a measured property, not a constant of nature. Published sharp-edged values span 0.60–0.65, and a plate installed with insufficient straight run, a burr on the edge, or gas entrained in the liquid can sit anywhere in that band. At Cd 0.60 versus 0.65, the same 100 kPa passes 39.6 or 42.9 GPM-equivalent — a 4 % swing with no change in the gauge reading.
Air and Gas Flow: The Choked-Flow Boundary
Gases compress, so the density the jet velocity is built from depends on the pressure itself. The calculator works from upstream conditions: ρ1 = P1/(Rs·T), where Rs = 8314.46/M is the specific gas constant (M in g/mol) and both pressures are absolute. With that density fixed, everything hinges on one ratio — P2/P1 — compared against the critical pressure ratio:
For air (k = 1.40) the critical ratio is 0.528: if downstream absolute pressure falls below 52.8 % of upstream, the gas hits sonic speed at the throat and the flow locks. The values below are computed from that formula and rounded to three decimals — you can reproduce each one from the equation:
| Gas | k — isentropic exponent | (P2/P1)crit |
|---|---|---|
| Air | 1.40 | 0.528 |
| Nitrogen (N₂) | 1.40 | 0.528 |
| Carbon dioxide (CO₂) | 1.30 | 0.546 |
| Methane (CH₄) | 1.31 | 0.545 |
Past the boundary, the calculator switches to the sonic (choked) equation — flow becomes proportional to upstream pressure alone:
Above the boundary, the subsonic branch applies, with the ISO 5167-style expansion factor Y accounting for the density change across the restriction:
The third preset — Air · 5 mm · 7 bar → 1 atm — walks the boundary in one click. P1 is 700 kPa absolute, P2 is 101.325 kPa absolute, so P2/P1 = 0.145, far below the 0.528 critical ratio: the badge turns red, the progress bar crosses the marker, and the choked equation delivers Qm ≈ 0.0201 kg/s ≈ 72.4 kg/h. Drop P2 from 101 to 50 kPa and nothing moves — the flow no longer knows what the downstream world is doing. The bar under the badge shows how much of the distance to choking remains, so you can see the boundary coming instead of hitting it.
Every pressure in the gas tab is absolute. Convert gauge readings first: psia = psig + 14.696, kPa(abs) = kPa(gauge) + 101.325, bar(abs) = bar(gauge) + 1.013. A P1 entered in gauge units makes the critical-ratio test meaningless — 7 bar gauge of air is 8.013 bar absolute, and the 10 % error lands directly on the choked verdict.
Sizing in Reverse: From Target Flow to Cv or Orifice Diameter
Most sizing jobs start at the wrong end: you know the flow you need and the pressure you can afford to spend, and the question is what restriction delivers it. Flip the direction toggle in the liquid tab and the same engine solves backwards:
Two short runs show the shape of the answers. First, a valve: a branch needs 12 GPM of water and the control loop can spare 2 psi across the valve. Cv = 12/√2 = 8.49 — scan the catalogue table below and a 1″ globe (Cv 15–25) covers it with room to spare, while a 1/2″ ball at the low end of its 20–40 band would be marginal at best. Second, an orifice: 10 L/min at 50 kPa of water needs a bore of 5.85 mm — in practice you drill the nearest standard size, 6.0 mm, and the flow lands a few percent above target because flow grows with the square of the bore.
Notice the asymmetry the reverse equations expose. The valve coefficient you need grows linearly with the target flow — double the duty, double the Cv. But it grows only as the inverse square root of the pressure you are willing to spend: the same flow at a quarter of the ΔP needs double the Cv. Bore demand behaves the same way, which is why a tank drained through a 6 mm hole takes roughly twice as long as through a 9 mm one, not half as long — the areas differ by barely 2.25×.
Don’t specify exactly the computed value. A valve sized at Cv 8.49 exactly has no margin for wear, for the SG drifting with temperature, or for the duty point moving next quarter. Pick the next standard size up — and then run the chosen device back through the forward direction, because the oversized valve will spend its extra capacity as throttling loss somewhere else in the loop.
Orifice Pressure Drop vs Permanent Pressure Loss
The ΔP you read across the taps is not what the pump has to pay for. Part of the drop is recoverable: downstream of the restriction, the jet slows and decelerates back into the full pipe, rebuilding some static pressure. The rest is converted to turbulence and heat, and that share — the permanent pressure loss — is what the system pays for on every cubic metre, forever.
The β ratio — bore over pipe diameter — decides how harsh the plate is. At β = 0.5 about 73 % of the reading is permanent; a tight β = 0.3 plate keeps roughly 90 % of the drop as loss; a loose β = 0.7 plate recovers its way down to about 49 %. A venturi’s recovery cone is the whole point of the device: it hands most of the dynamic pressure back, leaving a typical residue of 5–15 % of ΔP (typical range, device-dependent). A streamlined nozzle sits between the two — expect roughly 25–50 % of ΔP (typical range) to go permanent. These three figures are estimates, not standards calculations; the recovery depends on the exact geometry and the Reynolds number.
The practical consequence is a budgeting rule: a flow meter is not free. An orifice plate chosen for metering quietly adds a near-permanent tax to the line, and that tax belongs in the pump’s head calculation, not in a footnote. Fold the permanent loss into the line’s friction budget with the pipe sizing calculator, which adds it to the Darcy–Weisbach losses of the run so the pump duty point sees the whole bill.
Don’t size pump head from the gauge reading alone. The differential gauge tells you what the restriction sees; the pump feels the permanent share of it, plus every metre of pipe. A metering station that reads 100 kPa across the plate can be spending 73 kPa of that forever — size the head for the permanent part, verify the rest with the pipe model.
Cv, Kv, and Orifice Conversion Tables
The three numbers every orifice or valve calculation leans on — the discharge coefficient, the catalogue Cv, and the conversion between coefficient systems — with the data nature of each stated plainly, because a typical range quoted from a catalog and a value fixed by a standard deserve different levels of trust.
Typical discharge coefficients
| Device | Typical Cd (dimensionless) | Basis & data nature |
|---|---|---|
| Sharp-edged orifice plate | 0.60–0.65 | ISO 5167 plates — value moves with tap layout, β, and Reynolds number |
| Streamlined nozzle | 0.97–0.99 | ISA 1932 / long-radius nozzles — smooth entry suppresses the vena contracta |
| Venturi tube | 0.95–0.98 | Machined-convergent classical venturis — recovery cone returns most of the jet |
| Sharp pipe entrance (tank → pipe) | ≈ 0.82 | Classic entrance value from the 0.5 head-loss coefficient; rounded entries run higher |
Data nature: typical published ranges from the ISO 5167 device families and classic entrance-loss practice. The exact Cd of a given installation depends on tap layout, β, and Reynolds number — the calculator’s fixed defaults (0.62 / 0.97 / 0.975) sit at the practical midpoints.
Common valve Cv ranges
| Valve size | Style | Typical Cv (US GPM at 1 psi ΔP, water) |
|---|---|---|
| 1/2" | Ball | 20–40 |
| 3/4" | Ball | 35–55 |
| 1" | Ball | 80–110 |
| 1-1/2" | Ball | 160–220 |
| 2" | Ball | 350–500 |
| 1" | Globe | 15–25 |
| 2" | Globe | 60–90 |
| 2" | Butterfly | 100–300 |
Typical catalogue ranges — always confirm with the manufacturer datasheet. Trim profile, seat design, and even the same model in a different size move Cv by double- digit percentages; this table is for narrowing the shortlist, not for signing a purchase order.
Converting between the coefficient systems is exact enough at four digits: Kv = 0.865 × Cv, Cv = 1.156 × Kv. The conversion that people forget is the fluid one — the same Cv passes more of a lighter liquid: diesel (SG 0.84) flows about 9 % more GPM than water through the identical valve at the same ΔP, because Q scales with 1/√SG.
Spray Nozzle and Sprayer Tip Flow
A sprayer tip is a tiny calibrated orifice with its own naming convention, and it is the friendliest way to see the square-root law in daily work. The number stamped on an agspray tip is its flow in US GPM at 40 psi: an 015 tip passes 0.15 GPM at 40 psi, an 05 tip passes 0.5 GPM. That makes the tip a ready-made sprayer tip calculator reference — pick the tip, set the pressure, scale with √(P/40).
| Tip size (industry convention) | Flow at 40 psi (GPM) | Flow at 40 psi (L/min) | Flow at 60 psi (GPM) |
|---|---|---|---|
| 015 | 0.15 | 0.57 | 0.18 |
| 02 | 0.20 | 0.76 | 0.24 |
| 025 | 0.25 | 0.95 | 0.31 |
| 03 | 0.30 | 1.14 | 0.37 |
| 05 | 0.50 | 1.89 | 0.61 |
| 08 | 0.80 | 3.03 | 0.98 |
Data nature: industry naming convention (first digits = GPM at 40 psi), with the 60 psi column computed as rated × √(60/40) ≈ rated × 1.225 — the same square-root scaling the calculator applies to any orifice. Actual tips vary with wear and fan angle; calibrate against a jug before quoting an application rate.
The 60 psi column makes the √ΔP lesson concrete: raising tip pressure by 50 % buys only about 22 % more flow — and in field spraying it also shifts the droplet spectrum finer, raising drift risk for a modest gain in rate. When the datasheet speaks psi and your equipment speaks bar, or the rate book speaks L/ha and the tip table speaks GPM, run the numbers through the flow rate conversion calculator so the units change but the flow figure never does.
Check the pressure at the tip, not at the pump gauge. Every metre of hose and every fitting between them eats pressure, and the tip only responds to what arrives at its orifice — a 40 psi pump reading can be 32 psi at the boom, which is a 10 % flow error before drift or wear enter the picture.
Mistakes That Skew Real-World Results
The equation is the easy half. What separates a planning estimate from a number that survives commissioning is knowing where the real device departs from the model — and by how much. Five departures cover most of the surprises.
1. The coefficient is a snapshot, not a constant
Because flow is directly proportional to Cd (Q ∝ Cd at fixed ΔP and bore), any drift in the coefficient passes straight into the flow at the same percentage. A sharp-edged plate wears in service: erosion rounds the inlet edge, the vena contracta forms less tightly, and the effective Cd rises by 1–5 % — so the same gauge reading now delivers 1–5 % more flow than the datasheet predicted. Upstream disturbances push the other way: an elbow too close to the tap leaves swirl in the approach flow, the jet attaches irregularly, and Cd drops 1–5 %, quietly shrinking delivered flow. Entrained gas is the third mechanism — bubbles displace liquid volume and lower the effective density, so the mass delivery falls while the volumetric figure barely moves. None of these announce themselves; they are the difference between “the line runs 41 L/min” on paper and 39 or 43 in the field. This is why the ISO 5167 straight-run requirements exist, and why a metering plate gets re-calibrated instead of trusted for a decade.
2. The square-root law at scale
Doubling flow needs four times the pressure drop; ten times the flow needs one hundred times the ΔP. At household scale the law is gentle — 41.4 to 82.8 L/min for 100 to 400 kPa — but at process scale it becomes the dominant cost line: pushing a line from 10 to 100 m³/h through the same restriction means the restriction alone consumes a hundred-fold pressure multiple, and the pump pays it continuously. The flip side is the sizing asymmetry from the reverse section: the Cv you need scales linearly with flow but only as 1/√ΔP with the pressure you spend, which is why valve vendors can serve enormous flow ranges from a modest catalogue — capacity grows linearly while the pressure budget does the heavy lifting. Read any “just raise the setpoint” proposal against the square of what it implies.
3. Two hard limits the math cannot cross
The √ΔP law operates inside two boundaries, and both are safety lines rather than suggestions. For gases, the critical pressure ratio is the ceiling: once P2/P1 falls below ≈0.53 for air, the throat runs sonic, flow stops responding to downstream pressure, and every additional unit of ΔP is bought for nothing — the metering assumption behind the reading fails at exactly the moment the system is working hardest. For liquids, the cavitation threshold is the floor: when the static pressure at the vena contracta approaches the fluid’s vapour pressure, the liquid flashes to vapour, the flow reading goes unstable, and the collapsing bubbles pit and erode the plate or valve seat — metal removed by implosion, not corrosion. The calculator’s choked badge and cavitation flag mark these lines so you can design up to them, not through them.
4. What happens with impossible inputs
The calculator refuses to guess. Empty fields, zeros, and negative values — a bore of 0, a ΔP of −50, a density left blank — each raise a named error badge, and the results panel stays empty until the input is fixed; nothing is silently clamped to a default. Out-of-range values are rejected with the limit stated: bore above 1,000 mm, ΔP above 70 MPa (≈10,150 psi), density above 25,000 kg/m³, P2 ≥ P1 in gas mode, β outside 0–1, k outside 1.01–2. The reasoning is deliberate — a silently corrected number teaches the wrong lesson, while a named rejection tells you which physical impossibility you typed.
5. A cautionary chain: ignoring the CHOKED badge
Watch what happens when the boundary is ignored. A designer wants twice the mass flow from a gas relief orifice and, trusting √ΔP, plans four times the pressure drop. Below the critical ratio the plan is arithmetically correct and physically dead: the flow is already choked, so the actual mass flow stays flat no matter how hard the upstream pressure climbs — but the sizing spreadsheet, still scaling with √ΔP, reports the target met. The valve arrives undersized for the real duty, the upstream pressure accumulates instead of relieving, and the discrepancy surfaces during the one test you did not want it to. The red badge is the cheapest inspection this page performs: when it lights, stop scaling and start resizing the bore.
Don’t design a gas application past ≈0.9 × the critical ratio without checking the badge. Between 0.9 and 1.0 of the critical ratio the expansion approximation loses accuracy and the margin to choking is thinner than any gauge’s tolerance. Either accept the choked equation, or keep the operating point away from the boundary on purpose.
Each of these departures has a longer treatment in the guide library, which pairs every calculator on this site with the reading that explains its assumptions.
Worked Examples Recap
Every example on this page is reproducible in the calculator above through the preset buttons — the table below is the same math at rest, so you can verify the tool against the page (or the page against the tool) in either direction.
| Case | Inputs | Result |
|---|---|---|
| A — valve capacity | Cv 28 · SG 1.00 · ΔP 1 psi → 4 psi | 28 GPM at 1 psi → 56 GPM at 4 psi — √ΔP law: ΔP ×4 gives flow ×2 |
| B — sharp-edged orifice | d 10 mm · Cd 0.62 · water 998 kg/m³ · ΔP 100 kPa | 41.4 L/min ≈ 10.9 GPM · 2,477 kg/h · permanent loss ≈ 73.2 kPa at β 0.5 |
| C — choked air orifice | d 5 mm · Cd 0.62 · air k 1.40 · P1 700 kPa abs → P2 101.325 kPa abs · 20 °C | CHOKED (0.145 < 0.528) · 0.0201 kg/s ≈ 72.4 kg/h |
If your run of any preset lands more than a rounding step away from these figures, check the pressure-unit toggle first — kPa, psi, and bar differ by factors of 6.9 and 100, and that toggle is the single most common source of “the calculator disagrees with my hand calc”.
Data Sources & References
- ISO 5167 — Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full (orifice plates, nozzles, venturi tubes; discharge-coefficient classes and straight-run requirements). International Organization for Standardization (iso.org).
- IEC 60534 — Industrial-process control valves (flow-capacity sizing and valve-coefficient practice), together with ISA RP75-style Cv conventions. International Electrotechnical Commission (iec.ch) · International Society of Automation (isa.org).
- NIST — metric unit conversions and exact definitions underlying the GPM, L/min, kg/h, and lb/h factors on this page. NIST Metric Conversions (nist.gov).
- Crane Technical Paper No. 410 — Flow of Fluids through Valves, Fittings, and Pipe (K factors, entrance-loss values, and the √ΔP working charts generations of engineers carry). Crane Co. (craneco.com).
Published and maintained by the Flow Calculator team (Flow-Calculator.com). The fixed coefficients used by the tool (Cd 0.62 / 0.97 / 0.975, Kv = 0.865·Cv, β^1.9 loss approximation) are stated openly so any result can be traced back to its assumption — which is the entire point of this page.
Frequently Asked Questions
How does a Cv flow rate calculator work?▼
It applies the valve-coefficient definition directly: Cv is the US gallons per minute of water a fully open valve passes at a 1 psi drop, so any operating point follows Q = Cv·√(ΔP/SG). Enter the flow coefficient, the pressure drop, and the fluid's specific gravity, and the tool returns GPM and L/min at once. Run it in reverse — enter a target flow and the available drop — and it reports the Cv your valve catalogue needs to show, or the Kv equivalent in metric units.
How do I calculate orifice flow rate from pressure drop?▼
Multiply the bore area A = πd²/4 by the discharge coefficient Cd (about 0.62 for a sharp-edged plate) and by the jet velocity √(2ΔP/ρ). A 10 mm orifice with 100 kPa across water therefore discharges roughly 41.4 L/min (10.9 GPM). Set the bore and the two pressures in the liquid tab above and the live result updates on every keystroke — no chart lookup required.
What is the difference between Cv and Kv?▼
They measure the same capacity on two calibrations. Cv is quoted in US GPM of water at a 1 psi drop; Kv is quoted in m³/h of water at a 1 bar drop. Because 1 bar is about 14.5 times 1 psi, the numbers differ: Kv = 0.865 × Cv and Cv = 1.156 × Kv. Quoting the wrong coefficient shifts valve capacity by roughly 16 %, so always match the coefficient to the pressure unit in the equation you are using.
Why doesn't flow double when pressure doubles?▼
Flow through a fixed restriction scales with the square root of the pressure drop, not linearly. Doubling ΔP multiplies flow by √2 ≈ 1.41; quadrupling it doubles the flow. That is why a Cv 28 valve passes 28 GPM at 1 psi but needs a 4 psi drop to pass 56 GPM. To get twice the flow through the same valve you must accept four times the pressure loss — or select a larger coefficient.
What is permanent pressure loss and why is it larger than expected?▼
The ΔP measured across a restriction splits into a recoverable share (static pressure rebuilt downstream) and a share destroyed as turbulence and heat. A sharp orifice recovers little — at β 0.5 roughly 73 % of the reading is gone for good, while a venturi recovers down to a 5–15 % residue. Losses feel larger than expected because budgets get written from the gauge reading; the pump only ever feels the permanent share, and that share never comes back.
What does choked flow mean for my valve or orifice?▼
When the downstream absolute pressure falls below the critical fraction of the upstream pressure — about 0.528 for air and nitrogen — the gas reaches sonic speed at the throat. Downstream changes then stop affecting the flow: extra pressure drop buys nothing, and equations that keep scaling with √ΔP over-predict capacity. The gas tab flags the condition with a red CHOKED badge and switches to the sonic equation automatically, so the mass flow it reports stays honest.
More Flow Calculators
Pipe Sizing Calculator
Turn the pressure drop your orifice spends into a recommended line size with velocity and ΔP checks.
Flow Rate Conversion
Convert the Q this page returns between GPM, L/min, m³/h, SCFM, and kg/h — exact factors included.
Tank Fill & Drain Time
Use orifice outflow to estimate how fast a tank, pool, or rain barrel drains by gravity.
Open Channel Flow
The gravity-flow counterpart: Manning, weir, and culvert estimates with Froude number.
All Calculators
Every dedicated flow tool on the site, summarized on one hub page.
Sized the Restriction? Now Check the Line Around It.
The main flow rate engine takes the flow this page produces and answers the questions behind it: velocity in the recommended band, Reynolds regime, friction loss over the run, and pump power — live, on every keystroke.
By the Flow Calculator engineering team (Flow-Calculator.com) · Last updated: November 13, 2026